- Description
- Product Parameters
- Related Videos
About This Product
Glass bioreactors are equipment used to culture organisms such as microorganisms, animal cells, plant cells or algae. They are mainly used in biotechnology, pharmaceuticals, food industry and academic research. Due to its transparent glass structure, researchers can clearly observe the culture process inside the reactor, which is convenient for experimental operation and monitoring.
Working principle
Glass bioreactors provide an ideal environment for the growth of cells or microorganisms by precisely controlling parameters such as temperature, pH, stirring speed, dissolved oxygen, and gas supply. The culture medium in the reactor provides nutrients for the cells, and stirring and gas exchange ensure sufficient oxygen supply and exhaust gas discharge to maintain good growth conditions.
Design features
- Transparent glass structure: The glass material enables users to directly observe the growth in the reactor, especially in studying cell morphology, color changes of culture fluid, etc., providing obvious advantages.
- Chemical corrosion resistance: Glass materials have good corrosion resistance and are suitable for biological culture and chemical reactions in acidic and alkaline environments.
- A variety of sizes and designs: From small laboratory-scale bioreactors (such as 1-5 liters) to large industrial-scale reactors, glass bioreactors can be flexibly selected according to the needs of experiments or production.
- Aseptic operation design: The reactor is usually equipped with a variety of interfaces for aseptic sampling, nutrient solution replenishment and exhaust gas discharge to ensure the aseptic nature of the entire reaction process.
Main components
- Glass reaction vessel: Made of transparent glass, the capacity and shape of the reaction vessel vary depending on the application requirements.
- Stirring system: Through a mechanical stirrer or magnetic stirring system, the culture medium and gas are evenly distributed to avoid cell sedimentation or local nutrient deficiency.
- Temperature control system: A heating jacket or external heating element is used to maintain the temperature inside the reactor to support the optimal growth environment for organisms.
- Gas supply system: Through a gas diffuser or microporous bubbler, oxygen, carbon dioxide and other gases are supplied to ensure the normal respiration and metabolic processes of the cells.
- Sensor system: Used to monitor key parameters such as temperature, pH, dissolved oxygen concentration, stirring speed, etc. in the reactor. The automated control system can adjust these parameters to optimize the culture environment.
Application areas
- Biopharmaceuticals: Used for the research and development and production of biological products such as antibodies, protein drugs, and vaccines. Cultivating cells or microorganisms in a bioreactor can efficiently produce these biological preparations.
- Fermentation industry: Used to produce fermentation products such as enzymes, antibiotics, and amino acids, glass bioreactors provide a reliable experimental platform for laboratory research and development.
- Cell culture: Animal cells, plant cells, or microalgae can be cultured in glass bioreactors, which are widely used in agriculture, food technology, environmental protection, and other fields.
- Academic research: Glass bioreactors are commonly used equipment in academic research, supporting the study of various biochemical reactions and metabolic processes.
Model | OLT-GB-1 | OLT-GB-2 | OLT-GB-3 | OLT-GB-5 | OLT-GB-7 | OLT-GB-10 |
Liquid filling coefficient | 65-80%, 70% is the best | |||||
Total volume | 1.2L | 2.8L | 3.7L | 6.5L | 8.5L | 12.8L |
Working volume | 1L | 2L | 3L | 5L | 7L | 10L |
Stirring method | Mechanical stirring | |||||
Stirring speed range | 50-1000rpm | |||||
Impeller | Multistage impeller | |||||
Heating method | Chassis heating/silicone tape heating | |||||
Temperature range | Room temperature +5~75℃ | |||||
Measurement | Temperature, PH, DO, Defoaming | |||||
Peristaltic pump | 4 Adjusting PH (acid/alkali), deform, feeding | |||||
Vessel | GG-17&316L | |||||
Sterilization | In autoclave | |||||
Voltage | 220V/110V |
Custom sockets for different countries
Bioreactor Related Videos
Touch operation panel
Flow Meter
Peristaltic Pumps
Control System
Power switch knob
Mechanical stirring motor
Mechanical stirring system
Stirring paddle
Air inlet
DO electrode hole
Cooling water inlet
Sampling tube
Temperature sensor
Air outlet
Defoaming electrode
Cooling water outlet
PH electrode hole
Air inlet
Defoaming port
Feeding inlet
Alkali port
Acid port
Online sterilization
glass bioreactors & fermenters
BIOTECH Series Controllers
Series Project | 7000 Series | 8000 Series | ||
Apperance | ||||
Control Unit | PLC | PLC | ||
Interface | 10.1" touch screen with keyboard, mouse and printer ports | 15"touch screen, all-in-oneIndustrial computer with portfor keyboard, mouse and printer | ||
Data Storage | 5000 Hours | Unlimited | ||
Controllable Features | Online parameters: temperature (including automatic sterilization function), stirring speed, pH, dissolved oxygen, multi-channel feeding, defoaming, air flow, tank pressure, fermentation liquid weight, O, CO, methyl (ethyl) alcohol, bacterial count, RP detection, feeding weighing, etc. (other special parameters can be customized) | |||
Online calculation: OUR, CER, RQ, KLa, bacterial count, sugar, nitrogen, titer, etc. | ||||
Other functions: trend curve, historical curve, report, alarm management, data storage by batch number, password management, multi-batch analysis and comparison. | ||||
Recommend /Maxof connection | 1/2 | 1~4/4 | ||
BIOTECH-FCS FermentationAnalysis System | Need to connect to the upper management computer, which can be connected via LAN cable. One upper management computer can connect to multiple controllers for remote control via mobile phone APP | Built-in, can be connected to the host computer via LAN cable, one host management computer can connect up to 32 controllers | ||
Series Project | 9000 Series | 3000 Series | ||
Apperance | ||||
Control Unit | PLC | PLC | ||
Interface | 10.4" touch screen, all-in-one Industrial computer with port for keyboard, mouse and printer | 17"touch screen,Industrial computer withport for printer | ||
Data Storage | Unlimited | Unlimited | ||
Controllable Features | Online parameters: temperature (including automatic sterilization function), stirring speed, pH, dissolved oxygen, multi-channel feeding, defoaming, air flow, tank pressure, fermentation liquid weight, O, CO, methyl (ethyl) alcohol, bacterial count, RP detection, feeding weighing, etc. (other special parameters can be customized) | |||
Online calculation: OUR, CER, RQ, KLa, bacterial count, sugar, nitrogen, titer, etc. | ||||
Other functions: trend curve, historical curve, report, alarm management, data storage by batch number, password management, multi-batch analysis and comparison. | ||||
Recommend /Maxof connection | 1~4/4 | 1~6/Unlimited ( theoretically ) | ||
BIOTECH-FCS FermentationAnalysis System | Built-in, can be connected to the host computer via LAN cable, one host management computer can connect up to 32 controllers | |||